American Ultraviolet High-output DC Series germicidal fixtures are designed specifically for HVAC applications. They can be mounted in various configurations for optimum pass-by air decontamination and/or to irradiate cooling coils and drain pans.
Lamps and electronics can be accessed from outside the duct or plenum. ˇ§Greenˇ¨ lamps (contain 28mg of mercury) extend inside to span supply ducts and/or cooling coils.

Applications

DC Series fixtures are used for external installation in medium to large air handling systems in commercial, industrial, health care and institutional buildings. DC Series Fixtures are offered in two and four-lamp configurations. They may be mounted singly; in built-up banks; or in parallel configurations in a variety of locations, including coils, drain pans, ductwork, mixed air plenums and exhaust systems. The DC Series is available in five insertion depths (14ˇ¨, 16ˇ¨, 24ˇ¨, 33ˇ¨, and 45ˇ¨) and four voltage options (115, 208, 230 or 277 VAC), providing installation flexibility to accommodate virtually any system.

DC Series Fixtures are designed for easy access lamp changes that do not require you to un-mount housing from ducting - simply remove the rear access panel, slide over the lamp retaining clips and remove the lamps. All electronic components are housed outside the ducting, including lamp power connection, which eliminates moisture contamination. Lamps are rated for
two-year continuous operational life with approximately 20% drop in UVC output at end of lamp life

Benefits

  • Improves Indoor Air Quality (IAQ) by reducing bacteria, viruses and mold that either grow or pass through the air handling systems. Reduce the risk of cold, flu, allergies and other illness associated with air handling systems
  • ˇ§Greenˇ¨ lamps contain 28mg of mercury
  • Two-year (17,000 hours) guarantee on lamps with only 20% decrease
    in output over the two years
  • Five-year, non-prorated warranty on the ballast
  • Continuously cleans coils, drain pans, plenums and ducts,
    eliminating costly cleaning programs and the use of harmful
    chemicals and disinfectants
  • Reduces HVAC energy costs by restoring heat transfer and net
    cooling capacity
  • Produces no ozone or other secondary contaminants

DC SERIES SPECIFICATIONS:
Every DC fixture is manufactured and factory assembled in the U.S.A., and tested prior to shipment. Each assembly consists of housing, support bracket, electronic ballast(s), power cord and high output lamps.

FIXTURE: Housings are constructed of heavy gauge hospital grade stainless steel. Lamp changes can be done without removing the fixture from the mounting. All components are in one integrated assembly to maximize serviceability.

BALLAST: The solid-state electronic ballast (furnished with this series) is a Class P rapid start with a power factor minimum of .95. It is available as a 120, 208, 230, or 277 VAC 50/60 Hz and is designed to maximize photon production in air temperatures of 35 to 175 degrees F. Minimum ballast start temperature is minus 20 degrees F. Ballasts have a RFI - EMI rating as defined by FCC part 18A for industrial / commercial applications in regards to suppression. Ballasts are UL listed and suitable for use in air handling spaces.

LAMPS: DC Series UVC lamps are high-output (800mA), T5 tube diameter, and constructed from hard glass tubing for superior UV transmittance. Lamps are ˇ§greenˇ¨, containing 28mg of mercury (Hg) and they produce no ozone. Lamps shall retain, at minimum, 80% of initial output after 17,000 hours of use. Electrodes are designed to maximize plasma convection and stability for superior lamp performance. Lamps are rated to produce 11.7 microwatts/cm2 per linear inch of lamp arc length at a distance of one meter. This output has been independently tested in airstreams of 400 feet per minute velocities at temperatures of 45 degrees F.

INDEPENDENT TESTING: Units are tested in accordance with the general provisions of IES Lighting Handbook, 1981 Applications Volume, and provide output per 1" arc length of not less than 11.7 ŁgW/cm2 at 1 meter in a 400 fpm airstream of 45˘X F.

Download Duct Clean Series Brochure


ORDERING SPECIFICATIONS

Fixture
Insertion Depth
# of Lamps per Fixutre
Lamp Used
Voltage
DC14-2-277
14ˇ¨
2
SBL410
277
DC16-2-120
16ˇ¨
2
SBL430
120
DC16-2-230
16ˇ¨
2
SBL430
208/230
DC16-2-277
16ˇ¨
2
SBL430
277
DC24-2-120
24ˇ¨
2
SBL415
120
DC24-2-230
24ˇ¨
2
SBL415
208/230
DC24-2-277
24ˇ¨
2
SBL415
277
DC33-2-120
33ˇ¨
2
SBL420
120
DC33-2-230
33ˇ¨
2
SBL420
208/230
DC33-2-277
33ˇ¨
2
SBL420
277
DC45-2-120
45ˇ¨
2
SBL445
120
DC45-2-230
45ˇ¨
2
SBL445
208/230
DC45-2-277
45ˇ¨
2
SBL445
277
DC14-4-120
14ˇ¨
4
SBL410
120
DC14-4-230
14ˇ¨
4
SBL410
208/230
DC14-4-277
14ˇ¨
4
SBL410
277
DC16-4-120
16ˇ¨
4
SBL430
120
DC16-4-230
16ˇ¨
4
SBL430
208/230
DC16-4-277
16ˇ¨
4
SBL430
277
DC24-4-120
24ˇ¨
4
SBL415
120
DC24-4-230
24ˇ¨
4
SBL415
208/230
DC24-4-277
24ˇ¨
4
SBL415
277
DC33-4-120
33ˇ¨
4
SBL420
120
DC33-4-230
33ˇ¨
4
SBL420
208/230
DC33-4-277
33ˇ¨
4
SBL420
277
DC45-4-120
45ˇ¨
4
SBL445
120
DC45-4-230
45ˇ¨
4
SBL445
208/230
DC45-4-277
45ˇ¨
4
SBL445
277