OminiCure 1000
- 100W lamp with Intelli-Lamp cooling and monitoring for extended lamp
life (typically 2000 hours) and optimum performance
- Adjust the light output in 1% increments for setting intensity level
- Selectable bandpass filters
- Easy to use finger touch controls with LED display
- Automatic lamp striking
OmniCure 2000
OmniCure Series 2000 is the latest model from the OmniCure curing
platform, providing outstanding control features and new 200W lamp technology
with a guaranteed life of 2000 hours
- Optional EXFO R2000 Radiometer can be combined with the Series 2000 to calibrate
and set absolute irradiance levels.
- Closed-Loop Feedback technology automatically maintains exposure levels
for repeatable cures
- 2 lamp options; including one specially designed for tack-free surface
curing of acrylic adhesives.
- Ideal for automated processes; easily controlled externally from a PC
- Adjustable light output in 1% increments for precise control
NovaCure 2100
- Closed-Loop Feedback technology automatically maintains exposure levels
for repeatable cures
- Built-in radiometer to measure output from the Light Guide
- Four user-programmable presets for single exposure curing and StepCure®
software for multi-phase programming
- Intelli-Lamp cooling and monitoring for extended lamp life (typically
2000 hours) and optimum performance
- Selectable bandpass filters
- Typical power output at 320 to 500 nm:18 000 mW/cm² (with standard
filter
ActiCure 4000
- Closed-Loop Feedback technology automatically maintains exposure levels
for repeatable cures
- 100W lamp with Intelli-Lamp cooling and monitoring for extended lamp
life (typically 2000 hours) and optimum performance
- Iris for adjusting lamp output
- External interface for easy automation
- Selectable bandpass filters
- Typical power output at 320 to 500 nm: 18 000 mW/cm² (with standard
filter
Radiometer with Filters and Adaptor
R2000 with Adaptor
The new EXFO R2000 Radiometer can be combined with the OmniCure Series
2000 to provide a complete curing system with unmatched control and repeatability.
Special electronics built into the R2000 Radiometer allow for connection of
custom sensors for measuring light energy directly at the cure site.
- Wireless and/or serial communication with OmniCure Series 2000 to set irradiance
levels and calibrate system
- Proprietary detector system for accurate wideband measurements
- Proprietary optical interface that virtually eliminates beam profile dependence
- Light Guide detector and color coded adapters to insure accurate measurements
- Memory for storing data with PC software for downloading
R5000
The powerful, precise and portable Radiometer efficiently combines numerous
features, including a proprietary detector system for accurate wideband measurements
and a proprietary optical interface that virtually eliminates beam profile dependence.
In peak hold mode, the Radiometer identifies, measures and displays maximum
values in changing signals; in real-time mode, it enables tracking of varying
signals; and in relative mode, it references all measurements to a benchmark
value.
- Externally exchangeable bandpass filters
- Optical interface; collects light over a large area and numerical aperture
(NA)
- Accurate broadband measurement between 250 and 600 nm
Cure Ring Radiometer
The Cure Ring Radiometer complements your EXFO Cure Ring to provide the most
accurate form of process control for precision manufacturing. By enabling the
output power from the Cure Ring to be measured directly at the cure site, the
EXFO Cure Ring Radiometer ensures a repeatable process.
High Power Bifurbicated LightGuide
The new EXFO High-Power Fiber Light Guide supplys an equal distribution of
light energy to multiple cure sites from a single light source. New technology
provides over 50% more throughput power than industry-standard fiber guides
for greater flexibility in your curing process. In addition, these light guides
offer over 30% more power than standard multilegged liquid light guides and
do not require balancing.
- Equal output through multiple legs with no balancing
- Higher output power
- No Degradation and Longer lifetime then liquid Light Guides
- Transmits from 160nm to 1200nm - Extended range Light Guides no longer
required